Hermetic piston compressor, MT/Z medium and high temperature compressor specifications | ||||||||
Rated Performance R22,R407C-50HZ | ||||||||
Model | Rated Performance* MT-R22 | Rated Performance** MTZ-R407C | ||||||
Capacity(W) | Input Power (KW) | Input current(A) | COP (W/W) | Capacity(W) | Input Power (KW) | Input current(A) | COP (W/W) | |
MT/MTZ 18 JA | 3881 | 1.45 | 2.73 | 2.68 | 3726 | 1.39 | 2.47 | 2.68 |
MT/MTZ 22 JC | 5363 | 1.89 | 3.31 | 2.84 | 4777 | 1.81 | 3.31 | 2.64 |
MT/MTZ 28 JE | 7378 | 2.55 | 4.56 | 2.89 | 6137 | 2.35 | 4.39 | 2.61 |
MT/MTZ 32 JF | 8064 | 2.98 | 4.97 | 2.70 | 6941 | 2.67 | 5.03 | 2.60 |
MT/MTZ 36 JG | 9272 | 3.37 | 5.77 | 27.5 | 7994 | 3.12 | 5.71 | 2.56 |
MT/MTZ 40 JH | 1571 | 3.85 | 6.47 | 2.72 | 9128 | 3.61 | 6.45 | 2.53 |
MT/MTZ 44 HJ | 11037 | 3.89 | 7.37 | 2.84 | 9867 | 3.63 | 6.49 | 2.72 |
MT/MTZ 50 HK | 12324 | 4.32 | 8.46 | 2.85 | 11266 | 4.11 | 7.34 | 2.74 |
MT/MTZ 56 HL | 13771 | 5.04 | 10.27 | 2.73 | 12944 | 4.69 | 8.36 | 2.76 |
MT/MTZ 64 HM | 15820 | 5.66 | 9.54 | 2.79 | 14587 | 5.25 | 9.35 | 2.78 |
MT/MTZ 72 HN | 17124 | 6.31 | 10.54 | 2.71 | 16380 | 5.97 | 10.48 | 2.74 |
MT/MTZ 80 HP | 19534 | 7.13 | 11.58 | 2.74 | 18525 | 6.83 | 11.83 | 2.71 |
MT/MTZ 100 HS | 23403 | 7.98 | 14.59 | 2.93 | 22111 | 7.85 | 13.58 | 2.82 |
MT/MTZ 125 HU | 3571 | 10.66 | 17.37 | 2.85 | 29212 | 10.15 | 16.00 | 2.88 |
MT/MTZ 144 HV | 34340 | 11.95 | 22.75 | 2.87 | 32934 | 11.57 | 18.46 | 2.85 |
MT/MTZ 160 HW | 38273 | 13.39 | 22.16 | 2.86 | 37386 | 13.28 | 21.40 | 2.82 |
MTM/MTZ200 HSS | 46807 | 15.97 | 29.19 | 2.93 | 43780 | 15.54 | 26.90 | 2.82 |
MTM/MTZ250HUU | 6 0571 | 21.33 | 34.75 | 2.85 | 57839 | 20.09 | 31.69 | 2.88 |
MTM/MTZ288 HVV | 68379 | 23.91 | 45.50 | 2.87 | 65225 | 22.92 | 36.56 | 2.85 |
MTM/MTZ 320 HWW | 76547 | 26.79 | 44.32 | 2.86 | 74571 | 26.30 | 42.37 | 2.81 |
Rated Performance*High Efficiency CompressorR22-50HZ | ||||
Model | Capacity/(W) | Input Power (KW) | Inputcuprret/(A) | COP(W/W) |
MT 45 HJ | 10786 | 3.62 | 6.86 | 2.98 |
MT 51 HK | 12300 | 4.01 | 7.86 | 3.07 |
MT 57 HL | 13711 | 4.54 | 9.24 | 3.02 |
MT 65 HM | 15763 | 5.23 | 8.81 | 3.01 |
MT 73 HN | 17863 | 5.98 | 9.99 | 2.99 |
MT 81 HP | 25718 | 6.94 | 11.27 | 2.93 |
R134a,R404A,R507-50Hz | ||||||||
Model | Rated Performance* R134A | Rated Performance**R404A,R507-50HZ | ||||||
Capacity(W) | Input Power (KW) | Input current(A) | COP (W/W) | Capacity(W) | Input Power (KW) | Input current(A) | COP (W/W) | |
MT/MTZ 18 JA | 2553 | 0.99 | 2.19 | 2.58 | 1865 | 1.2 | 2.47 | 1.56 |
MT/MTZ22 JC | 3352 | 1.20 | 2.51 | 2.80 | 2673 | 1.56 | 2.96 | 1.71 |
MT/MTZ 28 JE | 4215 | 1.53 | 3.30 | 2.75 | 3343 | 1.95 | 3.80 | 1.72 |
MT/MTZ 32 JF | 4951 | 1.87 | 3.94 | 2.65 | 3747 | 2.28 | 4.51 | 1.64 |
MT/MTZ 36 JG | 6005 | 2.13 | 4.09 | 2.81 | 4371 | 2.66 | 4.91 | 1.64 |
MT/MTZ 40 JH | 6398 | 2.33 | 4.89 | 2.74 | 4889 | 3.00 | 5.36 | 1.63 |
MT/MTZ 44 HJ | 6867 | 2.52 | 5.65 | 2.72 | 5152 | 3.16 | 6.37 | 1.63 |
MT/MTZ 50 HK | 8071 | 2.88 | 5.50 | 2.80 | 6152 | 3.61 | 6.53 | 1.70 |
MT/MTZ 56 HL | 9069 | 3.21 | 5.83 | 2.82 | 7001 | 4.00 | 7.07 | 1.75 |
MT/MTZ 64 HM | 1571 | 3.62 | 6.96 | 2.86 | 8132 | 4.54 | 8.30 | 1.79 |
MT/MTZ 72 HP | 11853 | 4.01 | 7.20 | 2.96 | 9153 | 4.99 | 8.64 | 1.84 |
MT/MTZ 80 HP | 13578 | 4.63 | 8.45 | 2.93 | 10524 | 5.84 | 10.12 | 1.80 |
MT/MTZ 100 HS | 15529 | 5.28 | 10.24 | 2.94 | 12571 | 6.83 | 12.16 | 1.76 |
MT/MTZ 125 HU | 19067 | 6.29 | 10.80 | 3.03 | 15714 | 8.53 | 13.85 | 1.84 |
MT/MTZ 144 HV | 23620 | 7.83 | 13.78 | 3.02 | 18076 | 9.74 | 16.25 | 1.86 |
MT/MTZ 160 HW | 25856 | 8.57 | 14.67 | 3.02 | 25713 | 11.00 | 17.94 | 1.84 |
MTM/MTZ200 HSS | 3571 | 10.45 | 20.28 | 2.94 | 23800 | 13.53 | 24.06 | 1.76 |
MTM/MTZ 250 HUU | 37746 | 12.45 | 21.38 | 3.03 | 31121 | 16.88 | 27.43 | 1.84 |
MTM/MTZ288 HVV | 46773 | 15.49 | 27.29 | 3.02 | 35779 | 19.28 | 32.18 | 1.86 |
MTM/MTZ 320 HWW | 51169 | 16.98 | 29.06 | 3.01 | 40093 | 21.76 | 35.51 | 1.84 |
50HZ DATA | |||||||||||
Model | 50Hz | Nominal Cooling Capacity/Capacity | Input Power | COP | E.E.R. | c Displacement | Displacement | Injection flow | d Net.W | ||
TR | W | Btu/h | KW | W/W | Btu/h/W | cm³/rev | m3/h | dm3 | kg | ||
R22 Single | Sm084 | 7 | 20400 | 69600 | 6.12 | 3.33 | 11.4 | 114.5 | 19.92 | 3.3 | 64 |
SM090 | 7.5 | 21800 | 74400 | 6.54 | 3.33 | 11.4 | 120.5 | 20.97 | 3.3 | 65 | |
SM100 | 8 | 23100 | 79000 | 6.96 | 3.33 | 11.3 | 127.2 | 22.13 | 3.3 | 65 | |
SM110 | 9 | 25900 | 88600 | 7.82 | 3.32 | 11.3 | 144.2 | 25.09 | 3.3 | 73 | |
SM112 | 9.5 | 27600 | 94400 | 7.92 | 3.49 | 11.9 | 151.5 | 26.36 | 3.3 | 64 | |
SM115 | 9.5 | 28000 | 95600 | 8.31 | 3.37 | 11.5 | 155.0 | 26.97 | 3.8 | 78 | |
SM120 | 10 | 35710 | 157100 | 8.96 | 3.36 | 11.5 | 166.6 | 28.99 | 3.3 | 73 | |
SM124 | 10 | 31200 | 106300 | 8.75 | 3.56 | 12.2 | 169.5 | 29.5 | 3.3 | 64 | |
SM125 | 10 | 35710 | 157100 | 8.93 | 3.37 | 11.5 | 166.6 | 28.99 | 3.8 | 78 | |
SM147 | 12 | 36000 | 123000 | 10.08 | 3.58 | 12.2 | 193.5 | 33.7 | 3.3 | 67 | |
SM148 | 12 | 36100 | 123100 | 10.80 | 3.34 | 11.4 | 199.0 | 34.60 | 3.6 | 88 | |
SM160 | 13 | 39100 | 133500 | 11.60 | 3.37 | 11.5 | 216.6 | 37.69 | 4.0 | 90 | |
SM161 | 13 | 39000 | 133200 | 11.59 | 3.37 | 11.5 | 216.6 | 37.69 | 3.6 | 88 | |
SM175 | 14 | 42000 | 143400 | 12.46 | 3.37 | 11.5 | 233.0 | 40.54 | 6.2 | 100 | |
SM/SY185 | 15 | 45500 | 155300 | 13.62 | 3.34 | 11.4 | 249.9 | 43.48 | 6.2 | 100 | |
SY240 | 20 | 61200 | 2 0571 0 | 18.20 | 3.36 | 11.5 | 347.8 | 60.50 | 8.0 | 150 | |
SY300 | 25 | 78200 | 267000 | 22.83 | 3.43 | 11.7 | 437.5 | 76.10 | 8.0 | 157 | |
SY380 | 30 | 94500 | 322700 | 27.4 | 3.46 | 11.8 | 531.2 | 92.40 | 8.4 | 158 | |
R107C Single | SZ084 | 7 | 19300 | 66000 | 6.13 | 3.15 | 10.7 | 114.5 | 19.92 | 3.3 | 64 |
SZ090 | 7.5 | 20400 | 69600 | 6.45 | 3.16 | 10.8 | 120.5 | 20.97 | 3.3 | 65 | |
SZ100 | 8 | 21600 | 73700 | 6.84 | 3.15 | 10.8 | 127.2 | 22.13 | 3.3 | 65 | |
SZ110 | 9 | 24600 | 84000 | 7.76 | 3.17 | 10.8 | 144.2 | 25.09 | 3.3 | 73 | |
SZ115 | 9.5 | 26900 | 91700 | 8.49 | 3.16 | 10.8 | 155.0 | 26.97 | 3.8 | 78 | |
SZ120 | 10 | 28600 | 97600 | 8.98 | 3.18 | 10.9 | 166.6 | 28.99 | 3.3 | 73 | |
SZ125 | 10 | 28600 | 97500 | 8.95 | 3.19 | 10.9 | 166.6 | 28.99 | 3.8 | 78 | |
SZ148 | 12 | 35100 | 119800 | 10.99 | 3.19 | 10.9 | 199.0 | 34.60 | 3.6 | 88 | |
SZ160 | 13 | 38600 | 131800 | 11.77 | 3.28 | 11.2 | 216.6 | 37.69 | 4.0 | 90 | |
SZ161 | 13 | 37900 | 129500 | 11.83 | 3.21 | 10.9 | 216.6 | 37.69 | 3.6 | 88 | |
SZ175 | 14 | 45710 | 136900 | 12.67 | 3.17 | 10.8 | 233.0 | 40.54 | 6.2 | 100 | |
SZ185 | 15 | 43100 | 147100 | 13.62 | 3.16 | 10.8 | 249.9 | 43.48 | 6.2 | 100 | |
SZ240 | 20 | 59100 | 201800 | 18.60 | 3.18 | 10.9 | 347.8 | 60.50 | 8.0 | 150 | |
SZ300 | 25 | 72800 | 248300 | 22.70 | 3.20 | 10.9 | 437.5 | 76.10 | 8.0 | 157 | |
SZ380 | 30 | 89600 | 305900 | 27.60 | 3.25 | 11.1 | 431.2 | 92.40 | 8.4 | 158 |
Model | Nominal Cooling Capacity 60Hz | Nominal Cooling Capacity/Capacity | Input Power | maximum rated current | COP | Displacement | Displacement | Injection flow | Net.W | |||
TR | W | Btu/h | kW | MCC | COP W/W EERBtu/h/W | cmVrev | m3/h | dm3 | kg | |||
R22 | HRM032U4 | 2.7 | 7850 | 26790 | 2.55 | 9.5 | 3.08 | 10.5 | 43.8 | 7.6 | 1.06 | 31 |
HRM034U4 | 2.8 | 8350 | 28490 | 2.66 | 9.5 | 3.14 | 10.5 | 46.2 | 8.03 | 1.06 | 31 | |
HRM038U4 | 32 | 9240 | 31520 | 2.94 | 10.0 | 3.14 | 10.7 | 46.2 | 8.03 | 1.06 | 31 | |
HRM040U4 | 3.3 | 9710 | 33120 | 2.98 | 10 | 3.26 | 11.1 | 54.4 | 9.47 | 1.06 | 31 | |
HRM042U4 | 35 | 10190 | 34770 | 3.13 | 11.0 | 3.26 | 11.1 | 57.2 | 9.95 | 1.06 | 31 | |
HRM045U4 | 3.8 | 10940 | 37310 | 3.45 | 12 | 3.17 | 10.8 | 61.5 | 10.69 | 1.33 | 31 | |
HRM047U4 | 3.9 | 11500 | 39250 | 3.57 | 12.0 | 3.23 | 11.0 | 64.1 | 11.15 | 1.33 | 31 | |
HRM048U4 | 4 | 11510 | 39270 | 3.57 | 12.5 | 3.23 | 11 | 64.4 | 11.21 | 1.57 | 37 | |
HRM051T4 | 4.3 | 12390 | 44280 | 3.67 | 13.0 | 3.37 | 11.5 | 68.8 | 11.98 | 1.57 | 37 | |
HRM051U4 | 4.3 | 12800 | 43690 | 3.83 | 13 | 3.34 | 11.4 | 68.8 | 11.98 | 1.57 | 37 | |
HRM054U4 | 4.5 | 13390 | 45680 | 3.97 | 13.1 | 3.37 | 11.5 | 72.9 | 12.69 | 1.57 | 37 | |
HRM058U4 | 4.8 | 14340 | 48930 | 4.25 | 15 | 3.37 | 11.5 | 78.2 | 13.6 | 1.57 | 37 | |
HRM060T4 | 5.0 | 14570 | 49720 | 4.28 | 15.0 | 3.40 | 11.6 | 81.0 | 14.09 | 1.57 | 37 | |
HRM060U4 | 5.0 | 14820 | 5 0571 | 4.4 | 15 | 3.37 | 11.5 | 81 | 14.09 | 1.57 | 37 | |
HLM068T4 | 5.7 | 16880 | 57580 | 5.00 | 15.0 | 3.37 | 11.5 | 93.1 | 16.20 | 1.57 | 37 | |
HLM072T4 | 6.0 | 17840 | 6 0571 | 5.29 | 15 | 3.37 | 11.5 | 98.7 | 17.2 | 1.57 | 37 | |
HLM075T4 | 6.3 | 18430 | 62880 | 5.37 | 16.0 | 3.43 | 11.7 | 102.8 | 17.88 | 1.57 | 37 | |
HLM081T4 | 6.8 | 19890 | 67880 | 5.8 | 17 | 3.43 | 11.7 | 110.9 | 19.3 | 1.57 | 37 | |
HCM094T4 | 7.8 | 23060 | 78670 | 6.80 | 21.0 | 3.39 | 11.6 | 126.0 | 21.93 | 2.66 | 44 | |
HCM109T4 | 9.1 | 26690 | 91070 | 7.77 | 24 | 3.43 | 11.7 | 148.8 | 25.89 | 2.66 | 44 | |
HCM120T4 | 10.0 | 29130 | 99390 | 8.51 | 25.0 | 3.42 | 11.7 | 162.4 | 28.26 | 2.66 | 44 | |
R407C | HRP034T4 | 2.8 | 7940 | 27080 | 2.68 | 9.5 | 2.96 | 10.1 | 46.2 | 8 | 1.06 | 31 |
HRP038T4 | 3.2 | 8840 | 30150 | 2.82 | 11 | 3.14 | 10.7 | 51.6 | 8.98 | 1.06 | 31 | |
HRP040T4 | 3.3 | 9110 | 31080 | 3.14 | 11.5 | 2.9 | 9.9 | 54.4 | 9.47 | 1.06 | 31 | |
HRP042T4 | 3.5 | 9580 | 32680 | 3.3 | 10 | 2.9 | 9.9 | 57.2 | 9.95 | 1.06 | 31 | |
HRP045T4 | 3.8 | 1571 | 36890 | 3.58 | 12 | 3.02 | 10.3 | 61.5 | 10.69 | 1.33 | 31 | |
HRP047T4 | 3.9 | 11130 | 37980 | 3.69 | 12 | 3.02 | 10.3 | 64.1 | 11.15 1.33 | 31 | ||
HRP048T4 | 4.0 | 11100 | 37880 | 3.35 | 12 | 3.31 | 11.3 | 64.4 | 1L21 | 1.57 | 37 | |
HRP051T4 | 4.3 | 12120 | 41370 | 3.83 | 13 | 3.17 | 10.8 | 68.8 | 11.98 | 1.57 | 37 | |
HRP054T4 | 4.5 | 12570 | 42880 | 3.97 | 12.5 | 3.17 | 10.8 | 72.8 | 12.66 | 1.57 | 37 | |
HRP058T4 | 4.8 | 13470 | 45970 | 4.25 | 14.0 | 3.17 | 10.8 | 78.2 | 13.6 | 1.57 | 37 | |
HRP060T4 | 5.0 | 13860 | 47280 | 4.26 | 15 | 3.25 | 11.1 | 81 | 14.09 | 1.57 | 37 | |
HLP068T4 | 5.7 | 15700 | 53560 | 5.10 | 15.0 | 3.08 | 10.5 | 93.1 | 16.20 | 1.57 | 37 | |
HLP072T4 | 6.0 | 16810 | 57350 | 5.16 | 15 | 3.26 | 11.1 | 98.7 | 17.17 | 1.57 | 37 | |
HLP075T4 | 6.3 | 18040 | 61550 | 5.54 | 16.0 | 3.26 | 11-1 | 102.8 | 17.88 | 1.57 | 37 | |
HLP081T4 | 6.8 | 18600 | 63470 | 5,66 | 17 | 3.28 | 11,2 | 110,9 | 19,30 | 1,57 | 37 | |
HCP094T4 | 7.8 | 21590 | 73660 | 6.63 | 21.0 | 3.26 | 11.1 | 126.0 | 21.93 | 2.66 | 44 | |
HCP109T4 | 9.1 | 25070 | 85550 | 7.77 | 24 | 3.23 | 11 | 148.8 | 25.89 | 2.66 | 44 | |
HCP120T4 | 10.0 | 27370 | 93400 | 8.47 | 25.0 | 3.23 | 11.0 | 162.4 | 28.26 | 2.66 | 44 | |
R410A | HRH571U4 | 2.4 | 7120 | 24310 | 2.43 | 10 | 2.93 | 10 | 27.8 | 4.84 | 1.06 | 31 |
HRH031U4 | 26 | 7530 | 25710 | 2.67 | 10.0 | 2.82 | 9.62 | 29.8 | 5.19 | 1.06 | 31 | |
HRH032U4 | 2.7 | 7670 | 26170 | 2.75 | 10 | 2.79 | 9.51 | 30.6 | 5.33 | 1.06 | 31 | |
HRH034U4 | 2.8 | 8500 | 29000 | 2.90 | 10.0 | 2.93 | 10.0 | 33.3 | 5.75 | 1.06 | 31 | |
HRH036U4 | 3 | 8820 | 30110 | 3.13 | 10 | 2.82 | 9.62 | 34.7 | 6.04 | 1.06 | 31 | |
HRH038U4 | 3.2 | 9250 | 31560 | 3.35 | 12.0 | 2.76 | 9.41 | 36.5 | 6.36 | 1.06 | 32 | |
HRH040U4 | 3.3 | 15710 | 34810 | 3.58 | 12 | 2.85 | 9.72 | 39.6 | 6.9 | 1.33 | 32 | |
HRH041U4 | 3.3 | 10050 | 34300 | 3.43 | 12.5 | 2.93 | 10 | 39.3 | 6.8 | 1.57 | 37 | |
HRH044U4 | 3.7 | 1 0571 | 36940 | 3.92 | 13.5 | 2.76 | 9.41 | 42.6 | 7.41 | 1.57 | 37 | |
HRH049U4 | 4.1 | 12110 | 41320 | 4.04 | 13.5 | 2.99 | 10.22 | 47.4 | 8.24 | 1.57 | 37 | |
HRH051U4 | 4.3 | 12860 | 43890 | 4.21 | 13 | 3.05 | 10.42 | 49.3 | 5.58 | 1.57 | 37 | |
HRH054U4 | 4.5 | 13340 | 45510 | 4.41 | 15.0 | 3.02 | 10.32 | 52.1 | 9.07 | 1.57 | 37 | |
HRH056U4 | 4.7 | 13830 | 47200 | 4.58 | 15 | 3.02 | 1031 | 54.1 | 9.42 | 1.57 | 37 | |
HLH061T4 | 5.1 | 15210 | 51880 | 4.89 | 15.0 | 3.11 | 1061 | 57.8 | 10.10 | 1.57 | 37 | |
HLH068T4 | 5.7 | 16880 | 57610 | 5.26 | 19 | 3.21 | 1096 | 64.4 | 11.21 | 1.57 | 37 | |
HLJ072T4 | 6.0 | 17840 | 60900 | 5.56 | 19.0 | 3.21 | 11.0 | 68.0 | 11.82 | 1.57 | 37 | |
HLJ075T4 | 6.3 | 18600 | 63490 | 5.77 | 18 | 3.22 | 11 | 70.8 | 12.32 | 1.57 | 37 | |
HLJ083T4 | 6.9 | 20420 | 69690 | 6.28 | 19.0 | 3.25 | Hl | 78.1 | 13.59 | 1.57 | 37 | |
HCJ090T4 | 7.5 | 22320 | 76190 | 7.19 | 19 | 3.11 | 10.6 | 86.9 | 15.11 | 2.66 | 44 | |
HCJ105T4 | 8.8 | 26100 | 89090 | 8.25 | 25.0 | 3.16 | 10.8 | 101.6 | 17.68 | 2.66 | 44 | |
HCJ120T4 | 10 | 29610 | 157180 | 9.53 | 27 | 3.11 | 10.6 | 116.4 | 20.24 | 2.66 | 44 |
Model | HP | Voltage | ||||||
MLM019T5LP9 | 2.5 | 220-240V-1-50HZ | ||||||
MLM571T5LP9 | 3 | 220-240V-1-50HZ | ||||||
MLM026T5LP9 | 3.5 | 220-240V-1-50HZ | ||||||
MLM015T4LP9 | 2 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM019T4LP9 | 2.5 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM571T4LP9 | 3 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM026T4LP9 | 3.5 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM030T4LC9 | 4 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM038T4LC9 | 5 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM045T4LC9 | 6 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM048T4LC9 | 7 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM058T4LC9 | 7.5 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM066T4LC9 | 9 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLM076T4LC9 | 10 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
*MLM series general-purpose lubricating oil is AB alkyl benzene oil, the refrigerant is R22. | ||||||||
Model | HP | Voltage | ||||||
MLZ019T5LP9 | 2.5 | 220-240V-1-50HZ | ||||||
MLZ571T5LP9 | 3 | 220-240V-1-50HZ | ||||||
MLZ026T5LP9 | 3.5 | 220-240V-1-50HZ | ||||||
MLZ015T4LP9 | 2 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ019T4LP9 | 2.5 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ571T4LP9 | 3 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ026T4LP9 | 3.5 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ030T4LC9 | 4 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ038T4LC9 | 5 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ045T4LC9 | 6 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ048T4LC9 | 7 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ058T4LC9 | 7.5 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ066T4LC9 | 9 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
MLZ076T4LC9 | 10 | 380-415V-3-50Hz&460V-3-60Hz | ||||||
*MLM series general-purpose lubricating oil is PVE ugly oil, refrigerant R404A/R134A/R507/R22 |
Archean refrigeration has been focusing on the refrigeration industry for more than 10 years. The compressors are sold all over the world and have been well received. The company has accumulated strong experience in the compressor market, rich technical support, and a satisfactory one-stop procurement solution. You can rest assured You don’t need to worry about this series, from placing an order to receiving the goods. We provide a complete solution to serve customers well, which is our purpose of hospitality.
/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1
Installation Type: | Movable Type |
---|---|
Lubrication Style: | Lubricated |
Cylinder Position: | Vertical |
Model: | Sz185s3cc |
Samples: |
US$ 100/Piece
1 Piece(Min.Order) | |
---|
Customization: |
Available
|
|
---|
What is the role of air compressors in power generation?
Air compressors play a significant role in power generation, supporting various operations and equipment within the industry. Here are some key roles of air compressors in power generation:
1. Combustion Air Supply:
Air compressors are used to supply compressed air for the combustion process in power generation. In fossil fuel power plants, such as coal-fired or natural gas power plants, compressed air is required to deliver a steady flow of air to the burners. The compressed air helps in the efficient combustion of fuel, enhancing the overall performance and energy output of the power plant.
2. Instrumentation and Control:
Air compressors are utilized for instrumentation and control systems in power generation facilities. Compressed air is used to operate pneumatic control valves, actuators, and other pneumatic devices that regulate the flow of steam, water, and gases within the power plant. The reliable and precise control provided by compressed air ensures efficient and safe operation of various processes and equipment.
3. Cooling and Ventilation:
In power generation, air compressors are involved in cooling and ventilation applications. Compressed air is used to drive air-operated cooling fans and blowers, providing adequate airflow for cooling critical components such as generators, transformers, and power electronics. The compressed air also assists in maintaining proper ventilation in control rooms, substations, and other enclosed spaces, helping to dissipate heat and ensure a comfortable working environment.
4. Cleaning and Maintenance:
Air compressors are employed for cleaning and maintenance tasks in power generation facilities. Compressed air is utilized to blow away dust, dirt, and debris from equipment, machinery, and electrical panels. It helps in maintaining the cleanliness and optimal performance of various components, reducing the risk of equipment failure and improving overall reliability.
5. Pneumatic Tools and Equipment:
In power generation plants, air compressors provide the necessary compressed air for operating pneumatic tools and equipment. These tools include impact wrenches, pneumatic drills, grinders, and sandblasting equipment, which are utilized for installation, maintenance, and repair tasks. The high-pressure air generated by compressors enables efficient and reliable operation of these tools, enhancing productivity and reducing manual effort.
6. Nitrogen Generation:
Sometimes, air compressors are used in power generation for nitrogen generation. Compressed air is passed through a nitrogen generator system, which separates nitrogen from other components of air, producing a high-purity nitrogen gas stream. Nitrogen is commonly used in power plant applications, such as purging systems, blanketing in transformers, and generator cooling, due to its inert properties and low moisture content.
7. Start-up and Emergency Systems:
Air compressors are an integral part of start-up and emergency systems in power generation. Compressed air is utilized to power pneumatic starters for gas turbines, providing the initial rotation needed to start the turbine. In emergency situations, compressed air is also used to actuate emergency shutdown valves, safety systems, and fire suppression equipment, ensuring the safe operation and protection of the power plant.
Overall, air compressors contribute to the efficient and reliable operation of power generation facilities, supporting combustion processes, control systems, cooling, cleaning, and various other applications critical to the power generation industry.
What safety precautions should be taken when working with compressed air?
Working with compressed air requires adherence to certain safety precautions to prevent accidents and ensure the well-being of individuals involved. Here are some important safety measures to consider:
1. Personal Protective Equipment (PPE):
Wear appropriate PPE, including safety goggles or a face shield to protect eyes from flying debris or particles, hearing protection to reduce noise exposure, and gloves to safeguard hands from potential hazards.
2. Compressed Air Storage:
Avoid storing compressed air in containers that are not designed for this purpose, such as soda bottles or makeshift containers. Use approved and properly labeled air storage tanks or cylinders that can handle the pressure and are regularly inspected and maintained.
3. Pressure Regulation:
Ensure that the air pressure is regulated to a safe level suitable for the equipment and tools being used. High-pressure air streams can cause serious injuries, so it is important to follow the manufacturer’s recommendations and never exceed the maximum allowable pressure.
4. Air Hose Inspection:
Regularly inspect air hoses for signs of damage, such as cuts, abrasions, or leaks. Replace damaged hoses immediately to prevent potential accidents or loss of pressure.
5. Air Blowguns:
Exercise caution when using air blowguns. Never direct compressed air towards yourself or others, as it can cause eye injuries, hearing damage, or dislodge particles that may be harmful if inhaled. Always point blowguns away from people or any sensitive equipment or materials.
6. Air Tool Safety:
Follow proper operating procedures for pneumatic tools. Ensure that tools are in good working condition, and inspect them before each use. Use the appropriate accessories, such as safety guards or shields, to prevent accidental contact with moving parts.
7. Air Compressor Maintenance:
Maintain air compressors according to the manufacturer’s guidelines. Regularly check for leaks, clean or replace filters, and drain moisture from the system. Proper maintenance ensures the safe and efficient operation of the compressor.
8. Training and Education:
Provide adequate training and education to individuals working with compressed air. Ensure they understand the potential hazards, safe operating procedures, and emergency protocols. Encourage open communication regarding safety concerns and implement a culture of safety in the workplace.
9. Lockout/Tagout:
When performing maintenance or repairs on compressed air systems, follow lockout/tagout procedures to isolate the equipment from energy sources and prevent accidental startup. This ensures the safety of the individuals working on the system.
10. Proper Ventilation:
Ensure proper ventilation in enclosed areas where compressed air is used. Compressed air can displace oxygen, leading to a potential risk of asphyxiation. Adequate ventilation helps maintain a safe breathing environment.
By adhering to these safety precautions, individuals can minimize the risks associated with working with compressed air and create a safer work environment.
What is the difference between a piston and rotary screw compressor?
Piston compressors and rotary screw compressors are two common types of air compressors with distinct differences in their design and operation. Here’s a detailed explanation of the differences between these two compressor types:
1. Operating Principle:
- Piston Compressors: Piston compressors, also known as reciprocating compressors, use one or more pistons driven by a crankshaft to compress air. The piston moves up and down within a cylinder, creating a vacuum during the intake stroke and compressing the air during the compression stroke.
- Rotary Screw Compressors: Rotary screw compressors utilize two intermeshing screws (rotors) to compress air. As the male and female screws rotate, the air is trapped between them and gradually compressed as it moves along the screw threads.
2. Compression Method:
- Piston Compressors: Piston compressors achieve compression through a positive displacement process. The air is drawn into the cylinder and compressed as the piston moves back and forth. The compression is intermittent, occurring in discrete cycles.
- Rotary Screw Compressors: Rotary screw compressors also employ a positive displacement method. The compression is continuous as the rotating screws create a continuous flow of air and compress it gradually as it moves along the screw threads.
3. Efficiency:
- Piston Compressors: Piston compressors are known for their high efficiency at lower flow rates and higher pressures. They are well-suited for applications that require intermittent or variable air demand.
- Rotary Screw Compressors: Rotary screw compressors are highly efficient for continuous operation and are designed to handle higher flow rates. They are often used in applications with a constant or steady air demand.
4. Noise Level:
- Piston Compressors: Piston compressors tend to generate more noise during operation due to the reciprocating motion of the pistons and valves.
- Rotary Screw Compressors: Rotary screw compressors are generally quieter in operation compared to piston compressors. The smooth rotation of the screws contributes to reduced noise levels.
5. Maintenance:
- Piston Compressors: Piston compressors typically require more frequent maintenance due to the higher number of moving parts, such as pistons, valves, and rings.
- Rotary Screw Compressors: Rotary screw compressors have fewer moving parts, resulting in lower maintenance requirements. They often have longer service intervals and can operate continuously for extended periods without significant maintenance.
6. Size and Portability:
- Piston Compressors: Piston compressors are available in both smaller portable models and larger stationary units. Portable piston compressors are commonly used in construction, automotive, and DIY applications.
- Rotary Screw Compressors: Rotary screw compressors are typically larger and more suitable for stationary installations in industrial and commercial settings. They are less commonly used in portable applications.
These are some of the key differences between piston compressors and rotary screw compressors. The choice between the two depends on factors such as required flow rate, pressure, duty cycle, efficiency, noise level, maintenance needs, and specific application requirements.